Divided highway “Ourense-Celanova " - Measuring span deflection nº2 of a level crossing

Measuring span deflection nº2 of a level crossing, located in the PK 100+9M of the divided highway Ourense-Celanova, during a load test required before commissioning of the structure. In general, it should measure at least the arrow in all vain centers and descent support lines.

You are missing some Flash content that should appear here! Perhaps your browser cannot display it, or maybe it did not initialize correctly.

This test is to prove the validity of the Terrestrial Laser Scanner for the measurement of arrows during the load tests in concrete bridges.

Bottom view and viewing the original point cloud corresponding to the vain nº2